ÀÌÀü
355 2000A Ŭ·¥ÇÁ¹ÌÅÍ [FLUKE-355]
´ÙÀ½
À§·Î
 
   ·Î±×ÀÎ
   
 
 
 ÇöÀçÀ§Ä¡ : HOME   > °ø±¸,°èÃø±â
  > °èÃø±â
  > Å×½ºÅͱâ
  > Ŭ·¥ÇÁ¸ÞŸ
 355 2000A Ŭ·¥ÇÁ¹ÌÅÍ [FLUKE-355]
 
 2000A ac+dc true-rms, 1400A ac, 2000A dc·Î ½Å·Ú¼º ÀÖ°Ô ÃøÁ¤, »ç¿ëÀÚ º¸È£¸¦ À§ÇÑ CAT IV 600, CAT III 1000V ¾ÈÀüµî±Þ
 
 
ÆǸŰ¡°Ý 1,136,000 ¿ø(VATÆ÷ÇÔ)
¸ðµ¨¸í Fluke 355
Á¦Á¶¿ø FLUKE [ºê·£µå ¹Ù·Î°¡±â]
Àç°í ÆǸÅÁß
±¸¸Å¼ö·® EA  
 
Fluke-355/353 2000A Ŭ·¥ÇÁ¹ÌÅÍ

°í-Àü·ù ÃøÁ¤±â´É°ú Ä¿´Ù¶õ Áý°Ô¸¦ °¡Áö°í ÀÖ¾î »ê¾÷ ºÐ¾ß ¹× ¼³ºñ ¾îÇø®ÄÉÀ̼ǿ¡ ÀûÇÕÇÏ°Ô µðÀÚÀÎµÈ Å¬·¥ÇÁ¹ÌÅÍÀÔ´Ï´Ù.

Ture-RMS·Î ½Å·Ú¼º ÀÖ´Â ÃøÁ¤ÀÌ °¡´ÉÇÑ Fluke 355/353 Ŭ·¥ÇÁ¹ÌÅÍ´Â 2000A±îÁöÀÇ Àü·ù ÃøÁ¤À» À§ÇØ ¼±ÅÃÇÒ ¼ö ÀÖ´Â ÀåºñÀÔ´Ï´Ù. ÀϹÝÀûÀ¸·Î °í-Àü·ù ¾îÇø®ÄÉÀ̼ǿ¡¼­ ¹ß°ßÇÒ ¼ö ÀÖ´Â ±½Àº ÄÉÀÌºíµµ ½±°Ô ÃøÁ¤ÇÒ ¼ö ÀÖµµ·Ï Ä¿´Ù¶õ Àåºñ¸¦ °¡Áö°í ÀÖ½À´Ï´Ù. ¶ÇÇÑ, °í-Àü·ÂÀ» ÃøÁ¤ÇÒ ¶§ »ç¿ëÀÚ º¸È£¸¦ À§ÇÑ °ß°íÇÑ µðÀÚÀΰú CAT IV 600V, CAT III 1000V ¾ÈÀü µî±ÞÀÌ Æ¯º°È÷ Ãß°¡µÇ¾ú½À´Ï´Ù. 

Ư¡

- 2000A ac+dc true-rms, 1400A ac, 2000A dc·Î ½Å·Ú¼º ÀÖ°Ô ÃøÁ¤
- 50mmÀÇ Å« Áý°Ô·Î Å©°í ´Ù¾çÇÑ ÄÉÀÌºí¿¡ ÀûÇÕ
- »ç¿ëÀÚ º¸È£¸¦ À§ÇÑ CAT IV 600, CAT III 1000V ¾ÈÀüµî±Þ
- ÃÖ¼Ò, ÃÖ´ë, Æò±Õ ±â´É
- µð½ºÇ÷¹ÀÌ È¦µå ±â´É

Electrical specifications
Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 A Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 §Ù Resolution: 0.1 §Ù
Accuracy: 1.5 % + 5 digits
Range: 4 k§Ù Resolution: 1 §Ù
Accuracy: 1.5 % + 5 digits
Range: 40 k§Ù Resolution: 10 §Ù
Accuracy: 1.5 % + 5 digits
Range: 400 k§Ù Resolution: 100 §Ù
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)
  On at ¡Â 30 §Ù
  Off at ¡Ã 100 §Ù
Frequency measurement
Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger level Refer to current and voltage tables

*Add 2 % to error spec for CF > 2



• <Àý´ë ÁÖÀÇ> ¸ðµç »óÇ°Àº Á¦Ç° ºÒ·®ÀÌ ÀÖÀ» ¼öµµ ÀÖ½À´Ï´Ù. µû¶ó¼­ ¾î¶°ÇÑ °æ¿ì¿¡µµ »óÇ°°¡°Ý ÀÌ»óÀÇ º¸»óÀº ¾ø½À´Ï´Ù.
• ¸ðµç »óÇ°¿¡ ³³¶« µî, »óÇ°¿¡ º¯ÇüÀ» ÁÙ ¼ö ÀÖ´Â ¸ðµç ÀÛ¾÷ ÈÄ¿¡´Â. ºÒ·®ÀÌ ¹ß»ýÇÏ¿©µµ º¸»óÀº ¾ø½À´Ï´Ù.
• »ó±â Á¦Ç°ÀÇ »óÇ° °ü·Ã µ¥ÀÌŸ´Â Âü°í »çÇ×À̹ǷΠÁ¦Ç°¿¡ ´ëÇÑ Å×½ºÆ® ¹× Á¤È®ÇÑ ÀÚ·á È®ÀÎ ÈÄ »ç¿ëÇϽñ⠹ٶø´Ï´Ù.
• °ü·Ã µ¥ÀÌŸ¿¡ ´ëÇÑ ³»¿ë¿¡ ´ëÇØ ¹ß»ýÇÏ´Â ¹®Á¦¿¡ ´ëÇؼ­´Â ¹ýÀûÀΠåÀÓÀ» ÁöÁö ¾Ê½À´Ï´Ù.




¿¡½ºÅ©·Î ¼­ºñ½º